PLANET LS100 and LS200 LoRaWAN sensors are intended for environmental monitoring and data collection. Data such as temperature, humidity, illumination, and ingress/egress all impact the status of a facility or a device, whether it is a motor, a refrigeration unit, or even the networking gear itself. Sensors in the LS series mostly have IP65 and IP67 ratings, allowing them to be deployed in outdoor and industrial indoor environments. The number of sensors deployed depends on network requirements. The sensor(s) can monitor a wide variety of conditions, including humidity, leak detection, room temperature, machine temperature, product temperature, ingress and egress, lighting, occupancy and asset location. These battery-operated sensors with no wiring required are easy to install in any place.
Product | LS200-TH | LS200-PT | LS200-TC | |||
Wireless Transmission | ||||||
Technology | LoRaWAN | |||||
Frequency | EU868: 863–870 MHz US915: 902–928 MHz | |||||
TX Power | US915 AS923 AU915 | 20dbm 16dbm (optional) 20dbm (optional) | EU868 KR920 IN865 | 16dbm 14dbm (optional) 20dbm (optional) | ||
Rx Sensitivity | -136dBm (LoRa, Spreading Factor = 12, Bitrate = 293bps) -121dBm (FSK, Frequency Deviation = 5kHz, Bitrate = 1.2kbps) | |||||
Work Mode | OTAA/ABP Class A | |||||
Data Interfaces | ||||||
Power Supply | 2x 3.6V ER14505 AA battery in parallel (Battery not included) | |||||
Operating Voltage | DC 3.1V~3.65V | DC 3.1V~3.65V | DC 3.1V~3.65V | |||
Battery Life Time | 5 years (25C, 15-minute reports, TxPower=20dBm, SF10) | 4.8 Years (25C, 15-minute reports, TxPower=20dBm, SF10) | ||||
Standby Current | 24uA | 25uA | 34uA | |||
Wake-up Current (Typical value) | 6.99mA | 9.94mA | 7.33mA | |||
Low Battery Threshold | 3.2V | 3.2V | 3.2V | |||
Physical Characteristics | ||||||
Dimensions(L x W x H) | 112 x 65 x 28 mm | 112 x 88.19 x 32 mm | 112 x 88.19 x 32 mm | |||
Weight | 141 g | 141 g | 186g |
Sensor Dimensions | D: Ø16mm*L: 27mm, | - | - | |
Probe Info | - | PT1000 Platinum Thermal | Thermocouple Characteristic | |
Probe Temperature Detection Range | - | -70°C to 200°C | -40°C to 125°C | |
Probe Wire Length | - | 2m | 1m | |
Probe Dimensions | - | 5mm in diameter * 150mm in length, needle probe | - | |
Ingress Protection | IP65 | IP65 | IP65 | |
Operating Temperature | -20°C to 55°C | |||
Relative Humidity | <90% RH (non condensing) | |||
Storage Temperature | -40°C ~ 85°C | |||
Standards Conformance | ||||
Regulatory Compliance | CE RED, FCC PART 15B | TELEC, CB, C TUV US | CE RED, FCC PART 15B |