A rack/tower convertible UPS with line interactive topology, the CyberPower Smart App Sinewave PR1000LCDRT1U provides battery backup, power protection (using sine wave output), and surge protection for corporate servers, department servers, storage appliances, network devices, and telecom installations requiring Active PFC power source compatibility. The PR1000LCDRT1U uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR is essential in areas where power fluctuations occur frequently. The PR1000LCDRT1U comes with a three-year warranty and a $400,000 Connected Equipment Guarantee.
Features:
GENERAL | |
UPS Topology | Line Interactive |
Energy Saving | GreenPower UPS™ Bypass Technology |
Active PFC Compatible | Yes |
INPUT | |
Voltage | Nominal 120V VAC |
Frequency Range | 57 – 63 Hz |
Input Voltage Range | 80 – 150 VAC |
Plug Type | NEMA 5-15P |
Plug Style | Right Angle, 45° Offset Right |
Cord Length | 10 ft |
OUTPUT | |
VA | 1,000 VA |
Watts | 800 W |
Automatic Voltage Regulation | Boost 1 +30% Boost 2 +14% Buck -12% |
On Battery Voltage | 120 VAC ± 5% |
On Battery Frequency | 60 Hz ± 1% |
On Battery Waveform | Sine Wave |
Outlet Type | NEMA 5-15R |
Outlets - Total | 7 |
Outlets - Critical Load | 3 |
Outlets - Battery & Surge Protected | 6 |
Outlets - Surge-Only Protected | 1 |
Rated Power Factor | 0.8 |
Overload Protection | Internal Circuitry Limiting Circuit Breaker |
Transfer Time | 10ms |
BATTERY | |
Runtime at Half Load | 13 minutes |
Runtime at Full Load | 3.5 minutes |
Battery Type | Sealed Lead-Acid |
Battery Size | 6V/9Ah |
Hot-Swappable | Yes |
Battery Quantity | 4 |
User Replaceable | Yes |
Typical Recharge Time | Less than 6 hours (90% charged) |
Replacement Battery | RB0690X4B |
SURGE PROTECTION & FILTERING | |
Surge Suppression | 1,030 Joules |
EMI/RFI Filtration | Yes |
MANAGEMENT & COMMUNICATIONS | |
Multifunction LCD Panel | Displays: Current/Load Level, Runtime, Battery Level, Battery In Use, Input Voltage, Output Voltage, Overload, Silent Mode, Normal Mode |
HID Compliant USB Port | Yes |
Serial Port | Yes |
EPO Port | Yes |
LED Indicators | Power On, Wiring Fault |
Audible Alarms | On Battery, Low Battery, Overload |
Software | PowerPanel® Business Edition |
SNMP / HTTP Remote Monitoring | Yes, with optional RMCARD202, RMCARD203 or RMCARD205 |
PHYSICAL | |
Rack Size | 1U |
Form Factor | Rack |
Dimensions (WxHxD) (in.) | 17.25 x 1.75 x 19.5 |
Weight (lbs.) | 35.9 |
ENVIRONMENTAL | |
Operating Temperature | 32 – 104 °F (0 – 40 °C) |
Operating Humidity | 0 – 95% (non-condensing) |
Storage Temperature | 5 – 113 °F (-15 – 45 °C) |
Maximum Operating Elevation | 10,000 ft (3,000 m) |
Maximum Storage Elevation | 50,000 ft (15,000 m) |
AC Mode Thermal Dissipation | 63 BTU/Hr |
CERTIFICATIONS | |
Safety | UL1778 4th cUL CSA C22.2 No 107.3-05 FCC/DOC Class A |
Environmental | RoHS Compliant |
WARRANTY | |
Product Warranty | 3 Years Limited |
Connected Equipment Guarantee | Lifetime |
CEG Amount | $400,000 |