10W Single Output Industrial DIN Rail Power Supply, 12V.
Features:
MODEL | MDR-10-12 | ||
OUTPUT | DC VOLTAGE | 12V | |
RATED CURRENT | 0.84A | ||
CURRENT RANGE | 0 ~ 0.84A | ||
RATED POWER | 10W | ||
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | ||
VOLTAGE TOLERANCE Note.3 | ±3.0% | ||
LINE REGULATION | ±1.0% | ||
LOAD REGULATION | ±3.0% | ||
SETUP, RISE TIME Note.5 | 500ms, 30ms/230VAC 1000ms, 30ms/115VAC at full load | ||
HOLD UP TIME (Typ.) | 120ms/230VAC | 25ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 85 ~ 264VAC | 120 ~ 370VDC |
FREQUENCY RANGE | 47 ~ 63Hz | ||
EFFICIENCY (Typ.) | 81% | ||
AC CURRENT (Typ.) | 0.33A/115VAC | 0.21A/230VAC | |
INRUSH CURRENT (Typ.) | COLD START 35A/115VAC 70A/230VAC | ||
LEAKAGE CURRENT | <1mA / 240VAC | ||
PROTECTION | OVERLOAD | Above 105% rated output power | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | |||
OVER VOLTAGE | 13.8 ~ 16.2V | ||
Protection type : Shut down o/p voltage, re-power on to recover | |||
FUNCTION | DC OK ACTIVE SIGNAL (max.) | 9 ~ 13.5V / 40mA | |
ENVIRONMENT | WORKING TEMP. | -20 ~ +70℃ (Refer to "Derating Curve") | |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH | ||
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) | ||
VIBRATION | Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | ||
SAFETY & EMC (Note 4) | SAFETY STANDARDS | UL508, TUV EN60950-1 approved | |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH | ||
EMC EMISSION | Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3 | ||
EMC IMMUNITY | Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, EN55024,EN61000-6-1,EN61204-3, light industry level, criteria A | ||
OTHERS | MTBF | 584K hrs min. MIL-HDBK-217F (25℃) | |
DIMENSION | 22.5*90*100mm (W*H*D) | ||
PACKING | 0.17Kg; 72pcs/13.2Kg/0.91CUFT | ||
NOTE |
|