Mission critical applications demand the best power quality – Endeavor 5-10kVA systems deliver it in versatile, easily configurable packages that can be tailored to your specific needs.
Features:
Electrical Characteristics:
Digital Signal Processor
High Output Power Factor
Output T.H.D.
Overload Capacity
Independent Battery Bypass
Optional 240V Output
Other Features:
Minuteman Reliability for Large Applications
Key features include:
Model - 208/240V Output Only (120V Capable) | ED20000RTXLP |
---|---|
Maximum Power Capacity | 20000/18000 |
Topology | Double Conversion Online, True Sine Wave |
Input Plug Type | Hardwire Only (Hardwire Only) |
Output Outlet Type | Hardwire Only (8 - NEMA 5-15/20R, 1 - L6-20R, 1 - L6-30R) |
Input | |
---|---|
Single (1Φ 2W + G) | |
Nominal Voltage | 208VAC |
Acceptable Input Voltage | 0 - 300VAC |
Voltage Range | 180 - 280VAC |
Power Factor Correction | =99% at Full Load |
Frequency Limits | 40 to 70Hz at Full Load |
Low Voltage Transfer Point | 156/180 resets to Utility Power at 166/190VAC or higher |
High Voltage Transfer Point | 280VAC resets to Utility Power at 270VAC or lower |
Input Protection | Resettable Circuit Breaker |
Output: Online | |
---|---|
Voltage Range | 208VAC: 204 - 212VAC |
Voltage Regulation | Nominal +/-2% |
Frequency Range | 50/60Hz, auto sensing, +/-00.1Hz (unless synchronized to utility) |
Efficiency (On-Line Mode) | >90% (Full Load) |
Output: Battery | |
---|---|
Waveform Type | True Sine Wave |
Nominal Voltage | Default: 208VAC, User-selectable:220/230/240VAC |
Voltage Regulation | Nominal +/-2% (until Low Battery warning) |
Frequency | 50/60Hz, +/-0.1Hz |
Votlage T.H.D. | =2% (Linear Load) |
Dynamic Response | +/-5% @ 100% Load change in 30ms |
Transfer Time | 0 ms |
Slew Rate | =1Hz / second |
Crest Factor | 2.7 : 1 |
Overload Capacity | =106% - =110% for 10 minutes / =111% - =125% for 5 minutes / =126% - =150% for 30 seconds |
Battery | |
---|---|
System Voltage | 240VDC |
Runtime: Half Load (minutes) | 12 |
Runtime: Full Load (minutes) | 4 |
Surge Protection | |
---|---|
Surge Energy Rating | 1050J |
Surge Current Capability | 6500 Amps total |
Surge Response Time | 1.2µs normal mode; <50µs common mode |
Surge voltage let-through (as a percentage of an applied ANSI C62.41 Cat. B +/-4kV) | <10% |
Noise Filter | normal and common mode EMI/RFI suppression |
Audible Noise at 1m (3 ft.) | <60dBA |
Environmental | |
---|---|
Operating Temperature (max) | 0 to +40°C (+32 to +104°F) |
Storage Temperature | -15 to +50°C (+5 to +122°F) |
Operating/Storage Humidity | 0 ~ 95% Non-Condensing |
Operating Elevation | 0 to 2,000m (0 to +6,562 ft.) |
Storage Elevation | 0 to 15,000m (0 to +49,213 ft.) |
Surge Protection and Filtering | |
---|---|
Surge Energy Rating (Joules) | 254J |
Surge Protection | |
---|---|
Safety and Approvals | cTUVus (Conforms to UL1778 4th Edition & CSA 22.2 no. 107.3-05), RoHS 2 Certified |
EMC Verification | FCC Class B, CE Certified |
Warranty - Platinum Protection | Three-years parts, labor, and battery (non-prorated); 5-year extended plans available - $200,000 |