PWR-300A-IN | ||
AC Input | ||
Voltage | 90~264VAC | |
Frequency | 47~63Hz | |
Power factor | ≥0.95 | |
Input current | ≤4A@100VAC | |
Input protection | Input undervoltage、Input overvoltage | |
DC Output | ||
Voltage /Current | +12VDC/25A, +12Vsb/0.7A | |
Output power | 312W Max. | |
Output efficiency | ≥83%@220V AC/25 A | |
Line Regulation | ±1% | |
Load regulation | ±3% | |
Regulated voltage accuracy | ±5% | |
Dynamic responseovershoot | ±5%@25%~50%~25%or50%~100%~50%transient,recover time<250us | |
Current sharing rate | ±5% | |
Output protection | short circuitprotection, overloadprotection, overvoltage protection,hot plugprotection,Overtemperatureprotection | |
Other | ||
Indicator light | Normal: green on Abnormal: green off | |
Function | Support for 1+1 redundant backup, hot plug and load flow sharing | |
Working Temperature | 0~55℃ | |
Storage Temperature | -40~70℃ | |
Relative humidity | 10%~95% | |
Heat dissipation | Ventilating fan design, heat emission at back | |
Dimension (D×H×W) | 234.9mm × 40.13 mm ×101.6mm | |
Working altitude | 4000m | |
Certification | ||
EMC standards | EN55022, EN55024 | |
NEBS standards | GR-63-CORE ISSUE 2 | |
Safety standards | IEC60950-1, GB4943-2001 | |
Approved standards | UL, TUV, CE |