Minuteman - EC3000RTXL2U - UPS Online 3kVA/2700W 2U Rack/Tower Ext Runtime TAA Compliant
Part number:
EC3000RTXL2U
Price:

Experience reliable power protection with our advanced online UPS series, designed for true double-conversion performance. Extend uptime indefinitely with compatible external battery packs and stay informed with a user-friendly front panel LCD. TAA-compliant for Federal, State, and Local government use, it also features output receptacle control for optimized load management. Backed by a full 3-year warranty, including batteries, for complete peace of mind.


 

Features:

  • True online, double-conversion technology
  • Compact case design, (only 2U for all models), for high-density rack installations.
  • Compatible with external battery packs for unlimited runtimes
  • TAA compliant
  • Flexible installation format: Rack or Tower
  • Rackmount ears come attached to UPS
  • Easy-to-read LCD display
  • 0.9 output power factor
  • Highly-efficient, Economy Mode option
  • Output receptacles control
  • Independent Battery Bypass – allows the UPS to provide voltage regulation and spike/surge protection either with dead batteries or without batteries
  • Hot-swappable battery replacement
  • Cold Start capable
  • Automatic internal bypass
  • Simultaneous USB and RS232 communications
  • Compatible with Minuteman’s SentryHD software
  • SNMP compatible (with optional card)
  • Dedicated EPO port
  • Full three-year warranty (including batteries)
  • Green UPS design (RoHS and Energy Star compliant)
UPS ModelEC1000RTXL2UEC1500RTXL2UEC2000RTXL2UEC3000RTXL2U
GENERAL
TopologyDouble-conversion, On-line, True Sine Wave
VA Rating1,000VA1,500VA2,000VA3,000VA
Load Capacity900 Watts1,350 Watts1,800 Watts2,700 Watts
Power Factor0.9
Input (10ft. power cord)5-15P5-20PL5-30P
Receptacles(6) 5-15R(6) 5-15/20R(6) 5-15/20R / (1) L5-30R
Outlet Control(2) Independently controllable banks of (3) outlets, (L5-30R is Always On)
Installation TypeRack/Tower or Wall (with optional installation kit)
INPUT
Nominal Voltage120VAC
Acceptable Input Voltage0-160VAC
Frequency Range50/60Hz, ±6Hz, Auto-sensing
Power Factor Correction≥99% at full load
Efficiency

>90% Full Load, On-line Mode (AC – AC)
 

>96% Full Load, Economy Mode
 

OUTPUT (NON-BATTERY OPERATION)
Voltage Default120VAC (110/127VAC adjustable)
Voltage Regulation±2% of nominal voltage
Frequency Range50/60Hz, ±6Hz
Efficiency (Line Mode)>90% (Full Load)
OUTPUT (BATTERY OPERATION)
Nominal Voltage120VAC (110/127VAC adjustable)
Voltage RegulationNominal ±2% (until Low Battery Warning)
Frequency50/60Hz, ±0.2Hz (unless synchronized to utility)
Voltage T.H.D.≤3% (Full Linear Load)
BATTERIES
Battery TypeSealed, non-spillable, maintenance-free, valve-regulated lead acid
Replacement ModuleBM0069BM0070BM0071
Runtime (Half Load)10 Minutes15 Minutes10 Minutes10 Minutes
Runtime (Full Load)2 Minutes5 Minutes3 Minutes3 Minutes
Compatible Battery Packs

BP24RTXL2U
 

BP24V72RTEXL
 

BP48RTXL2U
 

BP48V36RTEXL

BP72RTXL2U

BP72V24RTEXL
 

ENVIRONMENTAL
Operating Temp. (Max)0° to 40°C (+32° to +104°F)
 
Operating Humidity10% to 90% Non-condensing
 
Operating Elevation0 to 3,000m (0 to +10,000 ft.)
 
PHYSICAL
UPS Size (LxWxH) in Inches and mm (with rack ears installed) 
 

16” x 18.9” x 3.5”
 

407 x 479 x 88mm
 

19.2” x 18.9” x 3.5”
 

487 x 479 x 88mm
 

23.7” x 18.9” x 3.5”

602 x 479 x 88mm

UPS Weight24.3 lbs. / 11 Kgs.
 
44.1 lbs. / 20 Kgs.
 
65.7 lbs. / 27 Kgs.
 
Battery Pack Size (LxWxH) in Inches

BP24RTXL2U: 17.3”x16.9”x3.5”
 

BP24V72RTEXL: 17.3”x26.8”x5.3”
 

BP48RTXL2U: 17.3”x16.9”x3.5”

BP48V36RTEXL: 17.3”x26.8”x5.3”

BP72RTXL2U: 17.3”x22.9”x3.5”
 

BP72V24RTEXL: 17.3”x26.8”x5.3”
 

Battery Pack Weights

BP24RTXL2U: 60 lbs. / 27.2 Kgs.

BP24V72RTEXL: 138.9 lbs. / 63 Kgs.
 

BP48RTXL2U: 60 lbs. / 27.2 Kgs.

BP48V36RTEXL: 138.9 lbs. / 63 Kgs.

BP72RTXL2U: 83.3 lbs. / 37.8 Kgs.

BP72V24RTEXL: 127.9 lbs. / 58 Kgs.
 

REGULATORY COMPLIANCE
Safety and Approvals

cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 /R: 2014), FCC Class A,

CE certified, Energy Star 2.0, DoE 10 CFR Part 430, RoHS2 (EU Directive 2011/65/EU)