This Armatura access control platform is designed for large-scale security deployments requiring centralized management of access points, users, biometrics, inputs, and outputs. It supports extensive third-party integration through RESTful API, OSDP reader communication, and common building management protocols.
Access control platform supporting up to 129 access points, 12,801 inputs and outputs, 400,000 users, and 50,000 biometric templates; programmable supervised input states with time zone management through Armatura One.
• Supports up to 129 access points for large access control deployments
• Supports up to 12,801 inputs and outputs
• Manages up to 400,000 users and 50,000 biometric templates
• Provides RESTful API support for third-party integration
• Supports OPC, BACnet, and Modbus building management communication protocols
Supervised and programmable input states can be configured as inactive, active, short, or open, with input timing managed through the Armatura One security platform. OSDP communication support allows integration with third-party readers, while DOP and DOC system integration expands building security interoperability.
The platform is suitable for enterprise-scale access control projects requiring extensive access point capacity, biometric enrollment, programmable inputs, and integration with third-party systems or building management infrastructure.
| Technical Specifications | |
| Model Name | AHEB-0808 |
| Primary Power | 12 - 24 VDC ± 20%, 550 mA maximum |
| RS-485 Connectivity | |
| Output | RS-485 standard / OSDP V2.2 Dedicated for AHSC-1000 / AHDU series controller communication |
| Input | RS-485 Input standard / OSDP V2.2 Dedicated for AHEB series IO expansion board communication |
| Number of Ports | |
| Ports | 1 x RS-485 8 x supervised input (AUX IN) 8 x relay output (AUX OUT) 1 x power Input (PWR IN) 1 x power output (PWR OUT) 1 x power detection (AC Fail) 1 x backup battery detection (BAT Fail) 1 x tamper input (TMPR) |
| Inputs | |
| Inputs | 8 relays 4 state supervision, resistor values (5% tolerance) Normally open contact: use 1.2k, 2.2k, 4.7k or 10k Normally closed contact: use 1.2k, 2.2k, 4.7k or 10k |
| Outputs | |
| Outputs | 8 relays, 8 x Form-C with dry contacts |
| AHSC / AHDU Interface | |
| Protocol | RS-485 Protocol |
| Power | 12 - 24 VDC ± 20%, 550 mA maximum |
| OSDP Mode | 9600-115200 bps, OSDP V2.2, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit Maximum cable length: 2,000 ft. (609.6m) |
| Data Inputs | OSDP supported Maximum cable length: 500 ft. (152m) |
| Cable Requirement | |
| Power & Relays | 12 - 24 VDC ± 20%, 550 mA maximum |
| RS-485 Port | 9600-115200 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit One twisted pair with drain wire and shield, 120 ohm resistance, 22-18 AWG Maximum cable length: 3937ft (1200m) |
| Mechanical | |
| Dimensions | 7.6” W x 4.6” L x 0.7” H (193 x 116 x 17.5mm) |
| Mounting | Wall Mount |
| Environmental Parameters | |
| Temperature | -22°F ~ 158°F (-30°C~70°C), Operating & Storage |
| Certification | CE, FCC, RoHS, UL294 |
| Security Rating | Data Storage Encrypted with Certified EAL6+ Crypto Chipset |
| Software Interface | |
| Supported Softwares | Armatura One Security System, Cielo365 (coming soon) |