EndeavorSeries: Double conversion, true sine wave, online UPS w/ Transformer and Battery Pack, rackmount/tower, LCD display, 5556VA/5000W, 208-240V input and 120/208-240V output, extended runtime capable, 3 min full load and 11 min half load runtime, 0.9 power factor, automatic internal bypass, Independent Battery Bypass, simultaneous communication options, SentryHD software included, 3-year standard product warranty
Mission critical applications demand the best power quality – Endeavor 5-10kVA systems deliver it in versatile, easily configurable packages that can be tailored to your specific needs.
Endeavor 5-10kVA Series Upgraded Features:
Electrical Characteristics :
Digital Signal Processor
High Output Power Factor
Output T.H.D.
Overload Capacity
Independent Battery Bypass
Optional 240V Output
Other Features:
Minuteman Reliability for Large Applications
Key features include:
| Model - 208/240V Output Only (120V Capable) | ED6000RTXL |
|---|---|
| Maximum Power Capacity | 6000VA / 5400W (5556VA / 5000W) |
| Topology | Double Conversion Online, True Sine Wave |
| Input Plug Type | Hardwire Only (Hardwire / L6-30P/pigtail cord included) |
| Output Outlet Type | (6 - NEMA 5-15/20R, 1 - L6-20R, 1-L6-30R) |
| Input | |
|---|---|
| Single (1Φ 2W + G) | |
| Nominal Voltage | 208VAC |
| Acceptable Input Voltage | 0 - 300VAC |
| Voltage Range | 156 - 280VAC |
| Power Factor Correction | =99% at Full Load |
| Frequency Limits | 40 to 70Hz at Full Load |
| Low Voltage Transfer Point | 156/180 resets to Utility Power at 166/190VAC or higher |
| High Voltage Transfer Point | 280VAC resets to Utility Power at 270VAC or lower |
| Input Protection | Resettable Circuit Breaker |
| Output: Online | |
|---|---|
| Voltage Range | 208VAC: 204 - 212VAC |
| Voltage Regulation | Nominal +/-2% |
| Frequency Range | 50/60Hz, auto sensing, +/-00.1Hz (unless synchronized to utility) |
| Efficiency (On-Line Mode) | >90% (Full Load) |
| Output: Battery | |
|---|---|
| Waveform Type | True Sine Wave |
| Nominal Voltage | Default: 208VAC, User-selectable:220/230/240VAC |
| Voltage Regulation | Nominal +/-2% (until Low Battery warning) |
| Frequency | 50/60Hz, +/-0.1Hz |
| Votlage T.H.D. | =2% (Linear Load) |
| Dynamic Response | +/-5% @ 100% Load change in 30ms |
| Transfer Time | 0 ms |
| Slew Rate | =1Hz / second |
| Crest Factor | 3 : 1 |
| Overload Capacity | =106% - =110% for 10 minutes / =111% - =125% for 5 minutes / =126% - =150% for 30 seconds |
| Battery | |
|---|---|
| System Voltage | 192VDC |
| Runtime: Half Load (minutes) | 11 |
| Runtime: Full Load (minutes) | 3 |
| Surge Protection | |
|---|---|
| Surge Energy Rating | 1050J |
| Surge Current Capability | 6500 Amps total |
| Surge Response Time | 1.2µs normal mode; <50µs common mode |
| Surge voltage let-through (as a percentage of an applied ANSI C62.41 Cat. B +/-4kV) | <10% |
| Noise Filter | normal and common mode EMI/RFI suppression |
| Audible Noise at 1m (3 ft.) | <60dBA |
| Environmental | |
|---|---|
| Operating Temperature (max) | 0 to +40°C (+32 to +104°F) |
| Storage Temperature | -15 to +50°C (+5 to +122°F) |
| Operating/Storage Humidity | 0 ~ 95% Non-Condensing |
| Operating Elevation | 0 to 2,000m (0 to +6,562 ft.) |
| Storage Elevation | 0 to 15,000m (0 to +49,213 ft.) |
| Surge Protection and Filtering | |
|---|---|
| Surge Energy Rating (Joules) | 140J |
| Surge Protection | |
|---|---|
| Safety and Approvals | cTUVus (Conforms to UL1778 4th Edition & CSA 22.2 no. 107.3-05), RoHS 2 Certified |
| EMC Verification | FCC Class B, CE Certified |
| Warranty - Platinum Protection | Three-years parts, labor, and battery (non-prorated); 5-year extended plans available - $200,000 |