8KVA/8KW, online double-conversion UPS, Sine wave output, 6U rack/tower convertible, 200-240V input and output, hardwire input terminal block, (3) NEMA L6-30R outlets, LCD control panel, RMCARD205 pre-installed, EPO, RS-32/USB, 3 year warranty.
The CyberPower Smart App Online OL8KRT is a 6U rack/tower UPS with double-conversion. It provides sine wave output to multiple types of critical IT infrastructure requiring seamless power protection. The OL8KRT is generator compatible and delivers consistent 200-240 V power with zero-transfer time. Automatic-bypass ensures connected equipment continues to operate seamlessly when an overload or internal fault is detected.
The OL8KRT features a removable LCD control panel to reposition it in a more convenient location (with optional DB-26 cable), and it has a RMCARD205 pre-installed network card. Smart-battery management charging technology increases battery life by up to 50%. Fast-charge technology helps replenish battery charge from 0-90% in five hours, regardless of the number of Extended Battery Modules (EBM) connected. The energy-saving GreenPower UPS™ ECO Mode allows the UPS to reach up to 96% efficiency to reduce power consumption and thermal dissipation. This UPS can use the BP240V30ART3U or BP240VL3U01 extended battery module for more runtime. The OL8KRT comes with a three-year warranty (including batteries) and a $300,000 connected equipment guarantee.
Features:
| GENERAL | |
| UPS Topology | Double Conversion |
| Energy Saving | Yes - ECO Mode Efficiency up to 96% |
| INPUT | |
| Nominal Voltage | 200 V to 240 V |
| Voltage Range | 120 V to 139 V, 0% to 25% load 140 V to 159 V, 0% to 50% load 160 V to 179 V, 0% to 75% load 180 V to 280 V, 0% to 100% load |
| Frequency Range | 40 Hz to 70 Hz (auto-sensing) |
| Power Factor | 0.99 |
| INPUT CONT. | |
| Cold Start | Yes |
| Backfeed Protection | Yes |
| Plug Type | Hardwire |
| OUTPUT | |
| VA | 8,000 (8 kVA) |
| Watts | 8,000 (8 kW) |
| Power Factor | 1 |
| Waveform (Battery Mode) | Sine wave |
| OUTPUT CONT. | |
| Nominal Voltage (Battery Mode) | 200, 208, 220, 230, 240 V ±2% (configurable) |
| Frequency | 50/60 Hz ±0.25 Hz (auto-sensing/configurable) |
| ECO Mode Bypass Voltage Range | ±10%, ±15% (configurable) |
| Harmonic Distortion (THD) | <3% at linear load, <5% at non-linear load |
| Crest Factor | 3:1 |
| Outlets - Total | 4 |
| Outlet Type | (3) NEMA L6-30R, (1) Hardwire Terminal Block |
| Overload Protection | Line Mode: 105% to 125% load for 1 min 126% to 150% load for 10 s Battery Mode: 105% to 130% load for 10 s 131% to 150% load for 2 s |
| Short Circuit Protection | UPS Output Cut off Immediately or Input Fuse/ Circuit Breaker Protection |
| Bypass | Internal Bypass (Automatic and Manual) |
| Transfer Time | 0 ms |
| BATTERY | |
| Runtime at Half Load | 12 min |
| Runtime at Full Load | 4.7 min |
| Battery Type | Sealed lead acid |
| Battery Size | 12 V/9 Ah |
| Battery Quantity | 20 |
| Replaceable | Yes |
| Replacement Battery | (2) RB1290X10 |
| Hot Swappable | Yes |
| Typical Recharge Time | 5 h (0% to 90%) |
| Smart Battery Management (SMB) Mode | Yes |
| Extended Battery Module | Optional BP240V30ART3U or BP240VL3U01 |
| SURGE PROTECTION AND FILTERING | |
| Surge Protection | 2430 Joules, IEC 61000-4-5 Level 3 |
| Phone / Network Surge Protection RJ11/RJ45 | 1-In/1-Out (Combo) |
| EMI/RFI Filtration | Yes |
| MANAGEMENT AND COMMUNICATION | |
| LCD Control Panel | Access 50 information status and configuration settings via the Information and Configuration Menus, in addition to an Event Log Menu. |
| Rotatable LCD Control Panel Option | Yes |
| Removable LCD Control Panel Option | Yes - Requires DB26 cable (not included) |
| HID Compliant USB Port | Yes |
| Serial Port | Yes |
| Emergency Power Off (EPO) Port | Yes |
| Dry Contact Port | Yes |
| Cables Included | USB cable, serial cable, phone cable |
| LED Indicators | Power On (White) Line Mode (Green) Battery Mode (Yellow) Bypass Mode (Yellow) Fault (Red) Replace Battery (Red) |
| Audible Alarms | Battery Mode, Battery Low, Overload, UPS Fault |
| Software | PowerPanel® Business Edition |
| Upgradeable Firmware | Yes |
| Expansion Slot | Yes - RMCARD205 pre-installed |
| PHYSICAL | |
| Form Factor | Rack / Tower Convertible (rotatable LCD) |
| Enclosure Construction | Steel |
| Rack Mounting Hardware | Included |
| PHYSICAL CONT. | |
| Dimensions (WxHxD, in) | 17 x 10.5 x 26 |
| Dimensions (WxHxD, mm) | 433 x 266 x 660 |
| Weight (lb) | 225.5 |
| Weight (kg) | 102.5 |
| Rack Units | 6U |
| Max. Mounting Rail Depth (in) | 36.02 |
| Max. Mounting Rail Depth (mm) | 915 |
| Min. Mounting Rail Depth (in) | 20.47 |
| Min. Mounting Rail Depth (mm) | 520 |
| SHIPPING DIMENSIONS | |
| Dimensions (WxHxD, in) | 23.62 x 25.12 x 35.43 |
| Dimensions (WxHxD, mm) | 600 x 638 x 900 |
| Weight (lb) | 279.4 |
| Weight (kg) | 126.7 |
| ENVIRONMENTAL | |
| Operating Temperature | 32°F to 104°F (0°C to 40°C) |
| Operating Relative Humidity | 0% to 90% (non-condensing) |
| ENVIRONMENTAL CONT. | |
| Operating Elevation | 0 ft to 10,000 ft (0 to 3,000 m) |
| Storage Temperature | -4°F to 113°F (-20°C to 45°C) |
| Storage Relative Humidity | 0% to 95% (non-condensing) |
| Storage Elevation | 0 ft to 50,000 ft (0 m to 15,000 m) |
| UPS Online Thermal Dissipation (100% load) | 3211 BTU/h |
| ECO Mode Thermal Dissipation (100% load) | 1019 BTU/h |
| Audible noise at 1 m from surface of unit | 38 dBA to 65 dBA (0% to 100% load) |
| CERTIFICATIONS | |
| Safety | UL 1778 5th Ed. CSA C22.2 NO.107.3-05 FCC Part 15 Class A |
| Environmental | ROHS Compliant |
| WARRANTY | |
| Product Warranty | Three-Years Limited |
| Extended 2-Year Warranty | Optional WEXT5YR-U20B |
| Connected Equipment Guarantee | Lifetime |
| CEG Amount | $300,000 |