EndeavorSeries: Double conversion, true sine wave, online UPS w/ 5kVA Max Transformer/Maintenance Bypass Switch and Battery Pack, rackmount/tower, LCD display, 6889VA/6200W, 208-240V input and 120/208-240V output, extended runtime capable, 5 min full load and 13 min half load runtime, 0.9 power factor, automatic internal bypass, Independent Battery Bypass, simultaneous communication options, SentryHDsoftware included, 3-year standard product warranty
Mission critical applications demand the best power quality – Endeavor 5-10kVA systems deliver it in versatile, easily configurable packages that can be tailored to your specific needs.
Features:
Electrical Characteristics :
Digital Signal Processor
High Output Power Factor
Output T.H.D.
Overload Capacity
Independent Battery Bypass
Optional 240V Output
Other Features:
Minuteman Reliability for Large Applications
Key features include:
| Model - 208/240V Output Only (120V Capable) | ED8000RTXL5TFMB | 
|---|---|
| Maximum Power Capacity | 8000VA / 7200W (6889VA / 6200W) | 
| Topology | Double Conversion Online, True Sine Wave | 
| Input Plug Type | Hardwire Only (Hardwire Only) | 
| Output Outlet Type | Hardwire Only (8 - NEMA 5-15/20R, 1 - L6-20R, 1 - L6-30R) | 
| Input | |
|---|---|
| Single (1Φ 2W + G) | |
| Nominal Voltage | 208VAC | 
| Acceptable Input Voltage | 0 - 300VAC | 
| Voltage Range | 180 - 280VAC | 
| Power Factor Correction | =99% at Full Load | 
| Frequency Limits | 40 to 70Hz at Full Load | 
| Low Voltage Transfer Point | 156/180 resets to Utility Power at 166/190VAC or higher | 
| High Voltage Transfer Point | 280VAC resets to Utility Power at 270VAC or lower | 
| Input Protection | Resettable Circuit Breaker | 
| Output: Online | |
|---|---|
| Voltage Range | 208VAC: 204 - 212VAC | 
| Voltage Regulation | Nominal +/-2% | 
| Frequency Range | 50/60Hz, auto sensing, +/-00.1Hz (unless synchronized to utility) | 
| Efficiency (On-Line Mode) | >90% (Full Load) | 
| Output: Battery | |
|---|---|
| Waveform Type | True Sine Wave | 
| Nominal Voltage | Default: 208VAC, User-selectable:220/230/240VAC | 
| Voltage Regulation | Nominal +/-2% (until Low Battery warning) | 
| Frequency | 50/60Hz, +/-0.1Hz | 
| Votlage T.H.D. | =2% (Linear Load) | 
| Dynamic Response | +/-5% @ 100% Load change in 30ms | 
| Transfer Time | 0 ms | 
| Slew Rate | =1Hz / second | 
| Crest Factor | 2.7 : 1 | 
| Overload Capacity | =106% - =110% for 10 minutes / =111% - =125% for 5 minutes / =126% - =150% for 30 seconds | 
| Battery | |
|---|---|
| System Voltage | 240VDC | 
| Runtime: Half Load (minutes) | 14 | 
| Runtime: Full Load (minutes) | 5 | 
| Surge Protection | |
|---|---|
| Surge Energy Rating | 1050J | 
| Surge Current Capability | 6500 Amps total | 
| Surge Response Time | 1.2µs normal mode; <50µs common mode | 
| Surge voltage let-through (as a percentage of an applied ANSI C62.41 Cat. B +/-4kV) | <10% | 
| Noise Filter | normal and common mode EMI/RFI suppression | 
| Audible Noise at 1m (3 ft.) | <60dBA | 
| Environmental | |
|---|---|
| Operating Temperature (max) | 0 to +40°C (+32 to +104°F) | 
| Storage Temperature | -15 to +50°C (+5 to +122°F) | 
| Operating/Storage Humidity | 0 ~ 95% Non-Condensing | 
| Operating Elevation | 0 to 2,000m (0 to +6,562 ft.) | 
| Storage Elevation | 0 to 15,000m (0 to +49,213 ft.) | 
| Surge Protection and Filtering | |
|---|---|
| Surge Energy Rating (Joules) | 254J | 
| Surge Protection | |
|---|---|
| Safety and Approvals | cTUVus (Conforms to UL1778 4th Edition & CSA 22.2 no. 107.3-05), RoHS 2 Certified | 
| EMC Verification | FCC Class B, CE Certified | 
| Warranty - Platinum Protection | Three-years parts, labor, and battery (non-prorated); 5-year extended plans available - $200,000 |